Methods for localization of failed fuel assemblies in MBIR reactor

UDC: 
621.039.564.5

Issue of journal:

Abstract: 

The paper describes the designed fuel element monitoring system for MBIR fast research reactor. The method for localization of failed fuel assemblies on the power operating reactor is proposed. As a result, the time of failed fuel assemblies search on shutdown reactor can be reduced. The method is based on monitoring of delayed neutrons emitted by fission products in coolant, and modeling of the loop distribution of liquid metal coolant.

References: 
1. Tret'jakov I.T., Lopatkin A.V., Romanova N.V. i dr. Ot BOR+60 k reaktoru MBIR: preemstvennost' i razvitie / Sbornik dokladov nauchno+tehnicheskogo seminara «Rol' reaktora BOR+60 v innovacionnom razvitii atomnoj otrasli». OAO «GNC NIIAR», g. Dimitrovgrad, 2 marta 2010 g.
2. Zajko I.V., Levchenko M.O., Lopatkin A.V. i dr. Nejtronno+fizicheskie osoben+ nosti aktivnoj zony MBIR // Atomnaja jenergija. – 2013. – Tom 114. – №4. –S. 188+ 191.
3. Obshhie polozhenija obespechenija bezopasnosti issledovatel'skih jadernyh us+ tanovok NP+033+01. Utverzhdeny Postanovleniem Gosatomnadzora Rossii ot16.01.2002 g. № 2.
4. Skomorohov A.O., Luk'janov D.A. Primenenie metoda perekompensacii dlja op+ redelenija mestopolozhenija negermetichnyh sborok v reaktorah na bystryh nejt+ ronah // Izvestija vuzov. Jadernaja jenergetika. – 2007. – №2. – S.39–43.
5. Luk'janov D.A., Skomorohov A.O., Voropaev A.I. i dr. Sistema jekspertnogo analiza dannyh po KGO tvjel reaktora BN+600 na baze centra tehnicheskoj podderzhki GNC RF+ FJeI // Bezopasnost' AJeS i podgotovka kadrov: tez. dokl. XII Mezhdunarodnoj konfe+ rencii, Obninsk, 4–7 oktjabrja 2011 g. – Obninsk : IATJe NIJaU MIFI, 2011. – Ch. 1. – S. 88–89.
6. Zhilkin A.S., Gur'ev S.A., Osipov S.L. i dr. Lokalizacija defektnyh TVS v aktivnoj zone reaktora BN+600 s pomoshh'ju sektornoj sistemy KGO // Izvestija vuzov. Jadernaja jenergetika. – 2011. – №1. – S.83–91.