The Investigation of the Acoustic Level Limit Switch of Coolant in the Integrated Stand of the KV–2

UDC: 
621.039.534

Issue of journal:

Abstract: 

The results of the level switch based on 24 point acoustic probes which monitored process into
the testing integrated unit KV2 threeyear operation was generalized. It has been estimated that
the developed level switch worked satisfactorily. They make possible monitoring the thermohydraulic
processes associated with vapor phase formation died to the increase of liquid level and steam
condensation into reactor.

References: 
1. Mel'nikov V.I., Drobkov V.P., Kontelev V.V. Akusticheskie metody diagnostiki gazozhidkostnyh potokov. – M.: Jenergoatomizdat, 2006. – 351 s.
2. Mel'nikov V.I., Duncev A.V., V'jugin A.B. Issledovanie akustozondovoj sistemy opredelenija urovnja kipjashhego vodjanogo teplonositelja//Izvestija vuzov. Jadernaja jenergetika. – 2002. – № 4. – S.100106.
3. Mel'nikov V.I. i dr. Issledovanie akustozondovogo signalizatora urovnja kipjashhego vodjanogo teplonositelja//Izvestija vuzov. Jadernaja jenergetika. – 2006. – № 1. – S. 2532.
4. Mitenkov F.M. Perspektivy razvitija korabel'noj jadernoj jenergetiki//Vestnik Rossijskoj akademii nauk. – 1996. – T. 66. – № 11. – S. 10021004.